Compare reaction turbines

All reaction turbines

CFM56-7B18 ✕ CF34-10A18 ✕
Family CFM56-7B
EASA ID 3CM029 11GE141
Aircraft Engine Manufacturer CFM International GE Aircraft Engines
Aircraft Engine Type Turbofan Turbofan
Comment Boeing 737 Next Generation
Dry Weight (kg) 2366
Diameter (mm) 1549
Max Rotating Diameter (mm) 1549
Length (mm) 2507
Wikipedia Article (URL) en.wikipedia.org/wiki/CFM_International_CFM56
Fuel Jet A Jet A-1
Fan Blades 24
Geared Fan No No
Low-Pressure Compressor Stages 3
High-Pressure Compressor Stages 9
Combustion Chamber 2253M21
High Pressure Compressor Stages 1
Low-Pressure Turbine Stages 4
Afterburner No No
Streams 2 2
Bypass Ratio 5.5 5.4
Overall Pressure Ratio 21.59 26.5
Maximum Takeoff Thrust (kN) 86.74 82.1
Hydrocarbon Take Off (g/kg fuel) 0.1 0.05
Hydrocarbon Climb Out (g/kg fuel) 0.1 0.08
Hydrocarbon Approach (g/kg fuel) 0.1 0.13
Hydrocarbon Idle (g/kg fuel) 3.5 5.67
Hydrocarbon Unitary Average (g/kN) 6.32 9.5
Hydrocarbon Unitary Sigma (g/kN) 0.55
Hydrocarbon Unitary Range (g/kN) 8.8-9.8
Hydrocarbon Unitary Characteristic (g/kN) 9.7 14.6
Hydrocarbon Unitary Characteristicto Regulatory (% of limit) 49.5 74.5
Hydrocarbon LTO (g) 549 776
Carbon Monoxide Take Off (g/kg fuel) 0.6 0.66
Carbon Monoxide Climb Out (g/kg fuel) 0.4 0.36
Carbon Monoxide Approach (g/kg fuel) 3.6 3.43
Carbon Monoxide Idle (g/kg fuel) 28.3 47.29
Carbon Monoxide Unitary Average (g/kN) 52.45 80.2
Carbon Monoxide Unitary SD (g/kN) 1.8
Carbon Monoxide Unitary Range (g/kN) 78.8-82.3
Carbon Monoxide Unitary Characteristic (g/kN) 64.4 98.5
Carbon Monoxide Unitary Characteristicto Regulatory (% of limit) 54.6 83.5
NOx Take Off (g/kg fuel) 19.2 19.47
NOx Climb Out (g/kg fuel) 16.6 16.72
NOx Approach (g/kg fuel) 9.1 8.26
NOx Idle (g/kg fuel) 4.3 3.58
NOx Unitary Average (g/kN) 39.99 37.4
NOx Unitary SD (g/kN) 0.43
NOx Unitary Range (g/kN) 36.9-37.7
NOx Unitary Characteristic (g/kN) 46.4 43.3
NOx Unitaryto Standard (% of limit) 55.8 46.6
NOx Unitaryto CAEP2 (% of limit) 69.7 58.2
NOx Unitaryto CAEP4 (% of limit) 85.8 68.9
NOx Unitaryto CAEP6 (% of limit) 97 78
NOx Unitaryto CAEP8 (% of limit) 118.4 90.2
NOx LTO (g) 3472 3070
Smoke Take Off (SN) 10.7 14.73
Smoke Climb Out (SN) 6.4 7.01
Smoke Approach (SN) 0 0.12
Smoke Idle (SN) 0 0.35
Smoke Max (SN) 10.7 14.7
Smoke Sigma (SN) 0.29
Smoke Range (SN) 14.5-15.1
Smoke Characteristic (SN) 13.8 19
Smoke Characteristicto Regulatory (% of limit) 56.1 76.1
Fuel Flow Take Off (kg/s) 0.854 0.826
Fuel Flow Climbout (kg/s) 0.714 0.684
Fuel Flow Approach (kg/s) 0.26 0.232
Fuel Flow Idle (kg/s) 0.097 0.086
Fuel LTO (kg) 344 315
Fuel Venting Compliant No Yes
Carbon Monoxide LTO (g) 4566 6589
Compressor Description 1 fan, 3-stage LP, 9-stage HP
Emissions Data Status C C
Engine Status Out of production Out of production
NOx Compliance Demonstration 2.3.2 e)
Turbine Description 1-stage HP, 4-stage LP