Compare reaction turbines

All reaction turbines

CFM56-7B18 ✕ Passport20-19BB1A ✕
Family CFM56-7B
EASA ID 3CM029 21GE185
Aircraft Engine Manufacturer CFM International General Electric Company
Aircraft Engine Type Turbofan Turbofan
Comment Boeing 737 Next Generation
Dry Weight (kg) 2366
Diameter (mm) 1549
Max Rotating Diameter (mm) 1549
Length (mm) 2507
Wikipedia Article (URL) en.wikipedia.org/wiki/CFM_International_CFM56
Fuel Jet A Jet A
Fan Blades 24
Geared Fan No No
Low-Pressure Compressor Stages 3
High-Pressure Compressor Stages 9
Combustion Chamber SAC
High Pressure Compressor Stages 1
Low-Pressure Turbine Stages 4
Afterburner No No
Streams 2 2
Bypass Ratio 5.5 5.8932
Overall Pressure Ratio 21.59 41.3981
Maximum Takeoff Thrust (kN) 86.74 84.1599
Hydrocarbon Take Off (g/kg fuel) 0.1 0.0139
Hydrocarbon Climb Out (g/kg fuel) 0.1 0.0099
Hydrocarbon Approach (g/kg fuel) 0.1 0.0167
Hydrocarbon Idle (g/kg fuel) 3.5 0.0402
Hydrocarbon Unitary Average (g/kN) 6.32 0.085
Hydrocarbon Unitary Sigma (g/kN) 0.03
Hydrocarbon Unitary Range (g/kN) 0.05-0.11
Hydrocarbon Unitary Characteristic (g/kN) 9.7 0.1106
Hydrocarbon Unitary Characteristicto Regulatory (% of limit) 49.5 0.5643
Hydrocarbon LTO (g) 549 7.154
Carbon Monoxide Take Off (g/kg fuel) 0.6 0.2903
Carbon Monoxide Climb Out (g/kg fuel) 0.4 0.2991
Carbon Monoxide Approach (g/kg fuel) 3.6 1.2178
Carbon Monoxide Idle (g/kg fuel) 28.3 11.0275
Carbon Monoxide Unitary Average (g/kN) 52.45 17.2272
Carbon Monoxide Unitary SD (g/kN) 1.954
Carbon Monoxide Unitary Range (g/kN) 15.35-19.86
Carbon Monoxide Unitary Characteristic (g/kN) 64.4 19.6276
Carbon Monoxide Unitary Characteristicto Regulatory (% of limit) 54.6 16.6336
NOx Take Off (g/kg fuel) 19.2 37.6005
NOx Climb Out (g/kg fuel) 16.6 28.7615
NOx Approach (g/kg fuel) 9.1 14.8107
NOx Idle (g/kg fuel) 4.3 6.5492
NOx Unitary Average (g/kN) 39.99 63.8248
NOx Unitary SD (g/kN) 0.4948
NOx Unitary Range (g/kN) 63.44-64.52
NOx Unitary Characteristic (g/kN) 46.4 70.1834
NOx Unitaryto Standard (% of limit) 55.8 57.1544
NOx Unitaryto CAEP2 (% of limit) 69.7 71.443
NOx Unitaryto CAEP4 (% of limit) 85.8 77.5974
NOx Unitaryto CAEP6 (% of limit) 97 84.5187
NOx Unitaryto CAEP8 (% of limit) 118.4 94.0549
NOx LTO (g) 3472 5371.488
Smoke Take Off (SN) 10.7 0.4853
Smoke Climb Out (SN) 6.4 0.3953
Smoke Approach (SN) 0 0.0407
Smoke Idle (SN) 0 0.0469
Smoke Max (SN) 10.7 0.5086
Smoke Sigma (SN) 0.405
Smoke Range (SN) 0.1-1
Smoke Characteristic (SN) 13.8 0.5965
Smoke Characteristicto Regulatory (% of limit) 56.1 2.4035
Fuel Flow Take Off (kg/s) 0.854 0.8012
Fuel Flow Climbout (kg/s) 0.714 0.6574
Fuel Flow Approach (kg/s) 0.26 0.2279
Fuel Flow Idle (kg/s) 0.097 0.0783
Fuel LTO (kg) 344 297.3228
Fuel Venting Compliant No Yes
Carbon Monoxide LTO (g) 4566 1449.837
Compressor Description 1 fan, 3-stage LP, 9-stage HP
Emissions Data Status C C
Emissions Data Superseded Yes
Emissions Superseded By 07P27GE241
Engine Status Out of production
NOx Compliance Demonstration 2.3.2 e)
Turbine Description 1-stage HP, 4-stage LP